This section contains the tutorials for the following tools: Block JIG Generator, Compare GDSII, Gerber to PCB, Make
Board Paneling, Metal Mask Manager, Mounting Data Extractor, Mounting Emulator, Router-Machine JIG Generator, Solder
Quantity Calculator, Soldering Pallet, Test Point Location Generator, and Underfill.
This section contains the tutorials for the following tools: BOM, CAM, Component Arrangement Plan, CP, Golden Sample,
Logic, PCB, Redmark+, and Worksheet Planner.
PollEx BOM is software that can import formatted text BOM or MS/Excel BOM and to use for searching components or check conjunction
with PCB design file.
PollEx CAM is a Gerber tool that can import Gerber and drill files to check and edit design. In addition, PollEx CAM supports to compare two Gerber files.
Redmark+ is a communication tool in the design modification by directly displaying on the layer or point that needs to be
revised or reviewed in the PCB design viewer (.PDBB).
This section contains the tutorials for the following tools: BOM, CAM, Component Arrangement Plan, CP, Golden Sample,
Logic, PCB, Redmark+, and Worksheet Planner.
PollEx Technical Cleanliness (TC) is an optional module of the
PollEx PCB and a reliability analyzing tool set for PCB
designs.
PollEx TC checks for visible residues called particles to
decreases short-term and long-term board problems and increase functionality. The
Checked results of PollEx TC can be exported into a well
formatted Excel spreadsheet. As a result, PollEx TC helps to
reduce defectiveness and increase productivity.
Launch PollEx PCB.
Open the PollEx PCB layout design file.
From the menu bar, click File > Open.
Navigate to the PollEx_New_Sample.pdbb file
located at
C:\Temp\Altair-PollEx\PollExTechnicalCleanliness.
Refer to the PollEx PCB manual to use the PollEx PCB viewer.
Execute Technical Cleanliness Input.
Click Option > Technical Cleanliness > Input.
Click Load and select the
TC_Input.teci file located at
C:\Temp\Altair-PollEx\PollExTechnicalCleanliness\TCI.
Click Start to run the Analysis.
PollEx TC checks where the design’s data input
rules and constraints apply.
Check the results.
The test results are displayed on the screen (Particle size &
locations). Figure 1.
Click the 400um(low) particle size.
In the result dialog bar, you can check detailed list information of NETS and
PINS, as well as its DISTANCE and AREA. When you click an item from the list, it
displays the highlighted location with its associated layers. Figure 2.
Save the test result.
Click Save Result > PollEx_New_Sample > Save.
To view, click Load and open the
PollEx_New_Sample.tecr file located at:
C:\Temp\Altair-PollEx\PollExTechnicalCleanliness\TCE.
Figure 3.
Export the test result.
Click Result report > File name (PollEx_New_Sample) to export the result to Excel.
To view, open the PollEx_New_Sample.xlsx file
located at:
C:\Temp\Altair-PollEx\PollExTechnicalCleanliness\TCE.