MESHF
Bulk Data Entry Defines options for user-defined input of frequency ranges used to define bands in adaptive meshing for acoustic Adaptive Perfectly Matched Layer (APML) analysis.
Format
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | 
|---|---|---|---|---|---|---|---|---|---|
| MESHF | MFID | FVAL | F | FRNG | F1 | F2 | |||
| FRNG | F1 | F2 | FVAL | F | |||||
| etc. | 
Example
As shown in the example below, FVAL and FRNG do
                not need to be defined in any particular order. Five frequency bands are defined in
                this example: [10.0,10.0], [20.0,40.0], [41.0,41.0], [50.0,50.0], [51.0,80.0]
        | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | 
|---|---|---|---|---|---|---|---|---|---|
| MESHF | 7 | FVAL | 10.0 | FRNG | 20.0 | 40.0 | |||
| FVAL | 41.0 | FVAL | 50.0 | ||||||
| FRNG | 51.0 | 80.0 | 
Definitions
| Field | Contents | SI Unit Example | 
|---|---|---|
| MFID | Mesh frequency identification number. This can be referenced
                                    on the MFID field of PACPML Bulk Data.  No default (Integer > 0)  | 
                                |
| FVAL | Flag indicating that a single frequency value (F) is to follow. | |
| F | Single frequency value to be a part of the frequency bands.
                                         No default (Real)  | 
                                |
| FRNG | Flag indicating that two frequency values (F1, F2) are to follow. | |
| F1, F2 | Two frequency values identifying a frequency range that
                                    defines a frequency band.  No default (Real)  | 
                                
Comments
- Any number of FVALs and FRNGs can be defined on this entry.