CpT
-
From the Post ribbon, click on the
Iso-Surfaces tool.
Figure 1. Figure 2. The Iso-Surfaces guide bar and Iso-Function guide panel open. -
From the Iso-Function guide panel, set the Iso
Variable to
time_avg_total_pressure_coefficient and the
Iso Value to 0.1, then press
the Calculate button.
The Display Properties micro-dialog opens in the Surface Coloring tab.
- From the Display Properties dialog, Surface Coloring tab, set the Display value to constant.
- From the Iso-Surfaces guide bar, click on the green check mark to accept.
- From the Post Browser, under , right click on the newly created Iso-Surface and rename as CpT, then hide.