Cp (Time-Averaged)

  1. From the Post Browser, under Boundary Collections > Flow Boundaries, right click on Vehicle and click Edit.
    The Display Properties dialog – Surface Coloring tab opens.
  2. From the Display Properties dialog – Surface Coloring tab, set the Display value to time_avg_pressure_coefficient.
  3. Set the Legend Type to Global.
  4. Toggle-on the Legend button.
  5. Set the Legend range from -1 to 1.
  6. Press the Legend button.
    Figure 1.
    The Legend micro-dialog opens.
  7. From the Legend micro-dialog, click on Colormap and under Name, change the value to Cool to Warm (Extended).
  8. From the Legend micro-dialog, click on Title, type Cp (time-averaged) in the Title field and check the Horizontal title check box.
  9. From the Legend micro-dialog, click on Format. Change the Precision value to 2 and the Colorbar labels value to Floating point.
  10. From the Legend micro-dialog, click on Display. Change the position to Upper Right Corner by clicking on the Upper Right Corner button, set the Orientation to Horizontal, and change the Length value to 0.2.
  11. From the Display Properties micro-dialog, switch to the Contour Line Display tab (third from the left on top).
    Figure 2.
  12. From the Display Properties Dialog – Contour Line Display Tab, toggle the Display button and set the Display value to 5.
  13. Set the value of Variable to time_avg_pressure_coefficient.
  14. Set the Contour Range from -1 to 1 and set Color to constant.
  15. From the Boundary Groups guide bar, click on the green check mark to accept.
  16. Cycle through the Left, Top, Bottom, Front, Rear views and capture images for each.