SPCOFF

Bulk Data Entry Defines degrees-of-freedom to be excluded from AUTOSPC.

Format

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
SPCOFF G1 C G2 C G3 C G4 C

Example

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
SPCOFF 13 234 14 5

Definition

Field Contents SI Unit Example
Gi Grid or scalar point identification number.

(Integer > 0)

C Component numbers.

(Integer zero or blank for scalar points, or up to six unique digits (0 < digit ≤ 6) may be placed in the field with no embedded blanks for grid points).

Comments

  1. Degrees-of-freedom on this entry will be excluded from AUTOSPC.
  2. If both SPC and SPCOFF are defined for the same degree-of-freedom, then SPC takes priority