MBSMNT
Bulk Data Entry Defines a constant scalar moment on two grid points along the specified vector.
Format
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | 
|---|---|---|---|---|---|---|---|---|---|
| MBSMNT | SID | G1 | G2 | T | G3/Vx | Vy | Vz | 
Example
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | 
|---|---|---|---|---|---|---|---|---|---|
| MBSMNT | 3 | 345 | 346 | 1.0 | 0 | 1.0 | 1.0 | 
Definitions
| Field | Contents | SI Unit Example | 
|---|---|---|
| SID | Load set
                                    identification number. No default (Integer > 0) | |
| G1 | Grid point
                                    identification number. No default (Integer > 0) | |
| G2 | Grid point
                                    identification number. No default (Integer > 0) | |
| T | Value of
                                        moment. (Real) | |
| G3 | Grid point
                                    identification number to optionally supply
                                    Vx, Vy, and
                                        Vz in conjunction with
                                        G1. (Integer > 0) | |
| Vx | X component of vector V | |
| Vy | Y component of vector V | |
| Vz | Z component of vector V | 
Comments
- MBSMNT applies a scalar action-reaction moment on G1 and G2 along the vector defined by Vx, Vy, and Vz.
- The action moment is applied to G1 and the reaction moment is applied to G2.
- Right hand rule defines the positive moment.