AELIST
Bulk Data Entry Defines a list of aerodynamic box IDs.
Format
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | 
|---|---|---|---|---|---|---|---|---|---|
| AELIST | SID | E | E | E | E | E | E | E7 | |
| E8 | etc. | 
Example
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | 
|---|---|---|---|---|---|---|---|---|---|
| AELIST | 14 | 200 | THRU | 610 | 621 | THRU | 730 | 900 | |
| 901 | 
Definitions
| Field | Contents | SI Unit Example | 
|---|---|---|
| SID | Aerodynamic list set identification number. (Integer > 0) | |
| Ei | List of aerodynamic box IDs. (Integer > 0 or THRU) | 
Comments
- The AELIST entry can be referenced by AESURF and SPLINEi entries. Refer to these entries for the meaning of the data provided.
- When the THRU option is used, all intermediate boxes should exist. The word THRU may not appear in field 3 or 9 (2 or 9 for continuation lines).
- Embedded Blank fields are not allowed.