Category: eDrives > Toolbox > Sensorless
Description: The Set AFT Parameter block lets you choose which parameter to set.
Parameter: Select from the following:
Parameter |
Description |
enableControl |
Tells the AFT that the outputs are used in a controller. |
enableRsEstimation |
Enables stator resistance estimation. This happens once after enableControl is activated. |
Flux |
Sets the current flux value from the AFT. |
FluxEst |
Not applicable. |
Ld |
Sets the current value of Ld. |
Lq |
Sets the current value of Lq. |
obsgain |
Sets the current observer gain used by the AFT and derived from the AFT gain.
obsgan = AFT gain / rated flux2 |
Rs |
Sets the current value of the user-set stator resistance. |
RsEst |
Not applicable. |
Rs_recalb_on |
Tells AFT which Rs value to use. If true, AFT uses the RsEst; if false, AFT uses Rs. RsEst is only available after having run enableRsEstimation. |
SpeedEst |
Not applicable. |