CoaxCylindersEndFaces

Leakage flux between the end planes of a inner solid cylinder and a coaxial outer hollow cylinder

    CoaxCylindersEndFaces

Library

Modelica/Magnetic/QuasiStatic/FluxTubes/Shapes/Leakage

Description

In [Ro41] the equations for determining the reluctance are summarized. As an alternative to the geometry based data a generic leakage model is provided in this library.

Parameters

CoaxCylindersEndFaces_0

NameLabelDescriptionData TypeValid Values

mo_r_0

r_0

Radius of inner solid cylinder

Scalar

mo_r_1

r_1

Inner radius of outer hollow cylinder

Scalar

mo_r_2

r_2

Outer radius of outer hollow cylinder

Scalar

mo_l_g

l_g

Radial gap length between both cylinders

Scalar

mo_t

t

Radial thickness of outer hollow cylinder

Scalar

CoaxCylindersEndFaces_1

NameLabelDescriptionData TypeValid Values

mo_abs_V_m

abs_V_m

abs_V_m

Structure

mo_abs_V_m/fixed

fixed

Cell of scalars

true
false

mo_abs_V_m/start

start

Cell of scalars

mo_arg_V_m

arg_V_m

arg_V_m

Structure

mo_arg_V_m/fixed

fixed

Cell of scalars

true
false

mo_arg_V_m/start

start

Cell of scalars

mo_abs_Phi

abs_Phi

abs_Phi

Structure

mo_abs_Phi/fixed

fixed

Cell of scalars

true
false

mo_abs_Phi/start

start

Cell of scalars

mo_arg_Phi

arg_Phi

arg_Phi

Structure

mo_arg_Phi/fixed

fixed

Cell of scalars

true
false

mo_arg_Phi/start

start

Cell of scalars

mo_omega

omega

omega

Structure

mo_omega/fixed

fixed

Cell of scalars

true
false

mo_omega/start

start

Cell of scalars

mo_R_m

R_m

R_m

Structure

mo_R_m/fixed

fixed

Cell of scalars

true
false

mo_R_m/start

start

Cell of scalars

mo_G_m

G_m

G_m

Structure

mo_G_m/fixed

fixed

Cell of scalars

true
false

mo_G_m/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

port_p

implicit

Positive quasi-static magnetic port

input

1

port_n

implicit

Negative quasi-static magnetic port

output

1