FundamentalWavePermabilitySensor

Sensor of fundamental wave permeability

    FundamentalWavePermabilitySensor

Library

Modelica/Magnetic/QuasiStatic/FluxTubes/Sensors/Transient

Description

This sensor is used to determined the effective fundamental wave permeability of a saturated lumped circuit reluctance. For this purpose the sensor is placed such way that the magnetic flux and the magnetic potential difference of the investigated reluctance are sensed. The area of cross section and the effective length of the investigated magnetic path have to be provided as parameters.

See example NonLinearInductor.

Parameters

FundamentalWavePermabilitySensor_0

NameLabelDescriptionData TypeValid Values

mo_f

f

Fundamental wave frequency

Scalar

mo_A

A

Area of cross section

Scalar

mo_l

l

Length

Scalar

FundamentalWavePermabilitySensor_1

NameLabelDescriptionData TypeValid Values

mo_mu

mu

mu

Structure

mo_mu/fixed

fixed

Cell of scalars

true
false

mo_mu/start

start

Cell of scalars

mo_mur

mur

mur

Structure

mo_mur/fixed

fixed

Cell of scalars

true
false

mo_mur/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

fluxP

implicit

Positive port of flux path

input

1

fluxN

implicit

Negative port of flux path

output

1

potentialP

implicit

Positive port of magnetic potential difference path

input

2

potentialN

implicit

Negative port of magnetic potential difference path

output

2

mu

implicit

Absolute permeability

output

3

mur

implicit

Relative permeability

output

4