ThyristorCenterTapmPulse
m pulse thyristor rectifier with center tap
Library
Modelica/Electrical/PowerConverters/ACDC
Description
General information about AC/DC converters can be found at the AC/DC converter concept
This is a m pulse thyristor rectifier with center tap. All voltage sources must have one interconnected plug (tap). This rectifiers works only with odd number of phases due the symmetry constrains of even phase numbers implemented in symmetricOrientation. See example Examples.ACDC.RectifierCenterTapmPulse.
Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_RonThyristor | RonThyristor | Closed thyristor resistance | Scalar | |
mo_GoffThyristor | GoffThyristor | Opened thyristor conductance | Scalar | |
mo_VkneeThyristor | VkneeThyristor | Thyristor forward threshold voltage | Scalar | |
mo_offStart | offStart | Boolean start value of variable thyristor_p[:].off | Vector | true |
mo_m | m | Number of phases | Scalar | |
mo_useHeatPort | useHeatPort | =true, if heatPort is enabled | Number | 0 |
mo_T | T | Fixed device temperature if useHeatPort = false | Scalar |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_useConstantEnable | useConstantEnable | true = disabled boolean input, use constantEnable | Number | 0 |
mo_constantEnable | constantEnable | Constant enabling of firing signals | Scalar | true |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_vAC | vAC | vAC | Structure | |
mo_vAC/fixed | fixed | Cell of vectors | true | |
mo_vAC/start | start | Cell of vectors | ||
mo_iAC | iAC | iAC | Structure | |
mo_iAC/fixed | fixed | Cell of vectors | true | |
mo_iAC/start | start | Cell of vectors | ||
mo_powerAC | powerAC | powerAC | Structure | |
mo_powerAC/fixed | fixed | Cell of vectors | true | |
mo_powerAC/start | start | Cell of vectors | ||
mo_powerTotalAC | powerTotalAC | powerTotalAC | Structure | |
mo_powerTotalAC/fixed | fixed | Cell of scalars | true | |
mo_powerTotalAC/start | start | Cell of scalars | ||
mo_vDC | vDC | vDC | Structure | |
mo_vDC/fixed | fixed | Cell of scalars | true | |
mo_vDC/start | start | Cell of scalars | ||
mo_iDC | iDC | iDC | Structure | |
mo_iDC/fixed | fixed | Cell of scalars | true | |
mo_iDC/start | start | Cell of scalars | ||
mo_powerDC | powerDC | powerDC | Structure | |
mo_powerDC/fixed | fixed | Cell of scalars | true | |
mo_powerDC/start | start | Cell of scalars | ||
mo_LossPower | LossPower | LossPower | Structure | |
mo_LossPower/fixed | fixed | Cell of scalars | true | |
mo_LossPower/start | start | Cell of scalars | ||
mo_T_heatPort | T_heatPort | T_heatPort | Structure | |
mo_T_heatPort/fixed | fixed | Cell of scalars | true | |
mo_T_heatPort/start | start | Cell of scalars | ||
mo_fire_p | fire_p | fire_p | Structure | |
mo_fire_p/fixed | fixed | Cell of vectors | true | |
mo_fire_p/start | start | Cell of vectors | ||
mo_enable | enable | enable | Structure | |
mo_enable/fixed | fixed | Cell of scalars | true | |
mo_enable/start | start | Cell of scalars |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
ac | implicit | AC input | input | 1 |
dc_p | implicit | Positive DC output | input | 2 |
fire_p | implicit | Firing signals of positive potential transistors | input | 3 |
Port 4 | implicit | Conditional heat port | input | mo_useHeatPort |
Port 5 | implicit | Enables fire and notFire | input | 1-mo_useConstantEnable |