ThyristorCenterTap2Pulse

Two pulse thyristor rectifier with center tap

    ThyristorCenterTap2Pulse

Library

Modelica/Electrical/PowerConverters/ACDC

Description

General information about AC/DC converters can be found at the AC/DC converter concept

This a two pulse thyristor rectifier with center tap. In order to operate this rectifier a voltage with center tap is required. The center tap has to be connected with the negative pin of the load. The circuit topology is the same as in Examples.ACDC.RectifierCenterTap2Pulse.

Parameters

ThyristorCenterTap2Pulse_0

NameLabelDescriptionData TypeValid Values

mo_RonThyristor

RonThyristor

Closed thyristor resistance

Scalar

mo_GoffThyristor

GoffThyristor

Opened thyristor conductance

Scalar

mo_VkneeThyristor

VkneeThyristor

Thyristor forward threshold voltage

Scalar

mo_offStart_p

offStart_p

Boolean start value of variable thyristor_p.off

Scalar

true
false

mo_offStart_n

offStart_n

Boolean start value of variable thyristor_n.off

Scalar

true
false

mo_useHeatPort

useHeatPort

=true, if heatPort is enabled

Number

0
1

mo_T

T

Fixed device temperature if useHeatPort = false

Scalar

mo_m

m

Number of phases

Scalar

ThyristorCenterTap2Pulse_1

NameLabelDescriptionData TypeValid Values

mo_useConstantEnable

useConstantEnable

true = disabled boolean input, use constantEnable

Number

0
1

mo_constantEnable

constantEnable

Constant enabling of firing signals

Scalar

true
false

ThyristorCenterTap2Pulse_2

NameLabelDescriptionData TypeValid Values

mo_vAC

vAC

vAC

Structure

mo_vAC/fixed

fixed

Cell of scalars

true
false

mo_vAC/start

start

Cell of scalars

mo_iAC

iAC

iAC

Structure

mo_iAC/fixed

fixed

Cell of scalars

true
false

mo_iAC/start

start

Cell of scalars

mo_powerAC

powerAC

powerAC

Structure

mo_powerAC/fixed

fixed

Cell of scalars

true
false

mo_powerAC/start

start

Cell of scalars

mo_vDC

vDC

vDC

Structure

mo_vDC/fixed

fixed

Cell of scalars

true
false

mo_vDC/start

start

Cell of scalars

mo_iDC

iDC

iDC

Structure

mo_iDC/fixed

fixed

Cell of scalars

true
false

mo_iDC/start

start

Cell of scalars

mo_powerDC

powerDC

powerDC

Structure

mo_powerDC/fixed

fixed

Cell of scalars

true
false

mo_powerDC/start

start

Cell of scalars

mo_LossPower

LossPower

LossPower

Structure

mo_LossPower/fixed

fixed

Cell of scalars

true
false

mo_LossPower/start

start

Cell of scalars

mo_T_heatPort

T_heatPort

T_heatPort

Structure

mo_T_heatPort/fixed

fixed

Cell of scalars

true
false

mo_T_heatPort/start

start

Cell of scalars

mo_enable

enable

enable

Structure

mo_enable/fixed

fixed

Cell of scalars

true
false

mo_enable/start

start

Cell of scalars

mo_fire_p

fire_p

fire_p

Structure

mo_fire_p/fixed

fixed

Cell of scalars

true
false

mo_fire_p/start

start

Cell of scalars

mo_fire_n

fire_n

fire_n

Structure

mo_fire_n/fixed

fixed

Cell of scalars

true
false

mo_fire_n/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

ac_p

implicit

Positive AC input

input

1

ac_n

implicit

Negative AC input

output

1

dc_p

implicit

Positive DC output

input

2

fire_p

implicit

Firing signal of positive potential transistor

input

3

fire_n

implicit

Firing signal of negative potential transistor

input

4

Port 6

implicit

Conditional heat port

input

mo_useHeatPort

Port 7

implicit

Enables fire and notFire

input

1-mo_useConstantEnable