DiodeCenterTapmPulse
m pulse diode rectifier with center tap
Library
Modelica/Electrical/PowerConverters/ACDC
Description
General information about AC/DC converters can be found at the AC/DC converter concept.
This is a m pulse diode rectifier with center tap. All voltage sources must have one interconnected plug (tap). This rectifiers works only with odd number of phases due the symmetry constrains of even phase numbers implemented in symmetricOrientation. The circuit topology is the same as in Examples.ACDC.RectifierCenterTapmPulse.
Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_m | m | Number of phases | Scalar | |
mo_RonDiode | RonDiode | Closed diode resistance | Scalar | |
mo_GoffDiode | GoffDiode | Opened diode conductance | Scalar | |
mo_VkneeDiode | VkneeDiode | Diode forward threshold voltage | Scalar | |
mo_useHeatPort | useHeatPort | =true, if heatPort is enabled | Number | 0 |
mo_T | T | Fixed device temperature if useHeatPort = false | Scalar |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_vAC | vAC | vAC | Structure | |
mo_vAC/fixed | fixed | Cell of vectors | true | |
mo_vAC/start | start | Cell of vectors | ||
mo_iAC | iAC | iAC | Structure | |
mo_iAC/fixed | fixed | Cell of vectors | true | |
mo_iAC/start | start | Cell of vectors | ||
mo_powerAC | powerAC | powerAC | Structure | |
mo_powerAC/fixed | fixed | Cell of vectors | true | |
mo_powerAC/start | start | Cell of vectors | ||
mo_powerTotalAC | powerTotalAC | powerTotalAC | Structure | |
mo_powerTotalAC/fixed | fixed | Cell of scalars | true | |
mo_powerTotalAC/start | start | Cell of scalars | ||
mo_vDC | vDC | vDC | Structure | |
mo_vDC/fixed | fixed | Cell of scalars | true | |
mo_vDC/start | start | Cell of scalars | ||
mo_iDC | iDC | iDC | Structure | |
mo_iDC/fixed | fixed | Cell of scalars | true | |
mo_iDC/start | start | Cell of scalars | ||
mo_powerDC | powerDC | powerDC | Structure | |
mo_powerDC/fixed | fixed | Cell of scalars | true | |
mo_powerDC/start | start | Cell of scalars | ||
mo_LossPower | LossPower | LossPower | Structure | |
mo_LossPower/fixed | fixed | Cell of scalars | true | |
mo_LossPower/start | start | Cell of scalars | ||
mo_T_heatPort | T_heatPort | T_heatPort | Structure | |
mo_T_heatPort/fixed | fixed | Cell of scalars | true | |
mo_T_heatPort/start | start | Cell of scalars |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
ac | implicit | AC input | input | 1 |
dc_p | implicit | Positive DC output | input | 2 |
Port 3 | implicit | Conditional heat port | input | mo_useHeatPort |