ThermalAmbientDCCE

Thermal ambient for DC machine with compound excitation

    ThermalAmbientDCCE

Library

Modelica/Electrical/Machines/Thermal/DCMachines

Description

Thermal ambient for DC machines with compound excitation to prescribe winding temperatures either constant or via signal connectors. Additionally, all losses = heat flows are recorded.

Parameters

ThermalAmbientDCCE_0

NameLabelDescriptionData TypeValid Values

mo_useTemperatureInputs

useTemperatureInputs

If true, temperature inputs are used; else, temperatures are constant

Number

0
1

mo_TDefault

TDefault

Default temperature

Scalar

mo_Ta

Ta

Temperature of armature

Scalar

mo_Te

Te

Temperature of (shunt) excitation

Scalar

mo_Tse

Tse

Temperature of series excitation

Scalar

ThermalAmbientDCCE_1

NameLabelDescriptionData TypeValid Values

mo_Q_flowArmature

Q_flowArmature

Q_flowArmature

Structure

mo_Q_flowArmature/fixed

fixed

Cell of scalars

true
false

mo_Q_flowArmature/start

start

Cell of scalars

mo_Q_flowCore

Q_flowCore

Q_flowCore

Structure

mo_Q_flowCore/fixed

fixed

Cell of scalars

true
false

mo_Q_flowCore/start

start

Cell of scalars

mo_Q_flowStrayLoad

Q_flowStrayLoad

Q_flowStrayLoad

Structure

mo_Q_flowStrayLoad/fixed

fixed

Cell of scalars

true
false

mo_Q_flowStrayLoad/start

start

Cell of scalars

mo_Q_flowFriction

Q_flowFriction

Q_flowFriction

Structure

mo_Q_flowFriction/fixed

fixed

Cell of scalars

true
false

mo_Q_flowFriction/start

start

Cell of scalars

mo_Q_flowBrush

Q_flowBrush

Q_flowBrush

Structure

mo_Q_flowBrush/fixed

fixed

Cell of scalars

true
false

mo_Q_flowBrush/start

start

Cell of scalars

mo_TArmature

TArmature

TArmature

Structure

mo_TArmature/fixed

fixed

Cell of scalars

true
false

mo_TArmature/start

start

Cell of scalars

mo_Q_flowShuntExcitation

Q_flowShuntExcitation

Q_flowShuntExcitation

Structure

mo_Q_flowShuntExcitation/fixed

fixed

Cell of scalars

true
false

mo_Q_flowShuntExcitation/start

start

Cell of scalars

mo_Q_flowSeriesExcitation

Q_flowSeriesExcitation

Q_flowSeriesExcitation

Structure

mo_Q_flowSeriesExcitation/fixed

fixed

Cell of scalars

true
false

mo_Q_flowSeriesExcitation/start

start

Cell of scalars

mo_Q_flowTotal

Q_flowTotal

Q_flowTotal

Structure

mo_Q_flowTotal/fixed

fixed

Cell of scalars

true
false

mo_Q_flowTotal/start

start

Cell of scalars

mo_T_e

T_e

T_e

Structure

mo_T_e/fixed

fixed

Cell of scalars

true
false

mo_T_e/start

start

Cell of scalars

mo_T_se

T_se

T_se

Structure

mo_T_se/fixed

fixed

Cell of scalars

true
false

mo_T_se/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

thermalPort

implicit

input

1

Port 2

implicit

Temperature of armature

input

mo_useTemperatureInputs

Port 3

implicit

Temperature of (shunt) excitation

input

mo_useTemperatureInputs

Port 4

implicit

Temperature of series excitation

input

mo_useTemperatureInputs