Conductor
Ideal linear electrical conductor
Library
Modelica/Electrical/Analog/Basic
Description
The linear conductor connects the branch voltage v with the branch current i by i = v*G. The Conductance G is allowed to be positive, zero, or negative.
Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_G | G | Conductance at temperature T_ref | Scalar | |
mo_T_ref | T_ref | Reference temperature | Scalar | |
mo_alpha | alpha | Temperature coefficient of conductance (G_actual = G_ref/(1 + alpha*(T_heatPort - T_ref)) | Scalar | |
mo_useHeatPort | useHeatPort | =true, if heatPort is enabled | Number | 0 |
mo_T | T | Fixed device temperature if useHeatPort = false | Scalar |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_v | v | v | Structure | |
mo_v/fixed | fixed | Cell of scalars | true | |
mo_v/start | start | Cell of scalars | ||
mo_i | i | i | Structure | |
mo_i/fixed | fixed | Cell of scalars | true | |
mo_i/start | start | Cell of scalars | ||
mo_LossPower | LossPower | LossPower | Structure | |
mo_LossPower/fixed | fixed | Cell of scalars | true | |
mo_LossPower/start | start | Cell of scalars | ||
mo_T_heatPort | T_heatPort | T_heatPort | Structure | |
mo_T_heatPort/fixed | fixed | Cell of scalars | true | |
mo_T_heatPort/start | start | Cell of scalars | ||
mo_G_actual | G_actual | G_actual | Structure | |
mo_G_actual/fixed | fixed | Cell of scalars | true | |
mo_G_actual/start | start | Cell of scalars |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
p | implicit | Positive electrical pin | input | 1 |
n | implicit | Negative electrical pin | output | 1 |
Port 3 | implicit | Conditional heat port | input | mo_useHeatPort |