PartialCheckValvePT1

    PartialCheckValvePT1

Library

HydraulicsByFluidon/Components/Valves/Base

Parameters

PartialCheckValvePT1_0

NameLabelDescriptionData TypeValid Values

mo_OpeningPressure

OpeningPressure

Opening pressure difference

Scalar

mo_MaxOpeningPressure

MaxOpeningPressure

Max. opening pressure difference

Scalar

mo_NominalVolumeFlow

NominalVolumeFlow

Nominal volume flow

Scalar

mo_NominalPressureDifference

NominalPressureDifference

Nominal pressure difference

Scalar

mo_resistorType

resistorType

Type of the resistor

Structure

mo_resistorType/choice1

Orifice

Number

0
1

mo_resistorType/choice2

Throttle

Number

0
1

mo_ReferenceDensity

ReferenceDensity

Reference density for volume flow and pressure difference

Scalar

mo_TimeConstant

TimeConstant

Time constant of the first order delay

Scalar

mo_deadVolume

deadVolume

Dead volume at ports

Scalar

PartialCheckValvePT1_1

NameLabelDescriptionData TypeValid Values

mo_forwardFluidProperties

forwardFluidProperties

Forward fluid properties between ports

Scalar

true
false

PartialCheckValvePT1_2

NameLabelDescriptionData TypeValid Values

mo_volumeFlowA

volumeFlowA

volumeFlowA

Structure

mo_volumeFlowA/fixed

fixed

Cell of scalars

true
false

mo_volumeFlowA/start

start

Cell of scalars

mo_volumeFlowB

volumeFlowB

volumeFlowB

Structure

mo_volumeFlowB/fixed

fixed

Cell of scalars

true
false

mo_volumeFlowB/start

start

Cell of scalars

mo_pA

pA

pA

Structure

mo_pA/fixed

fixed

Cell of scalars

true
false

mo_pA/start

start

Cell of scalars

mo_pB

pB

pB

Structure

mo_pB/fixed

fixed

Cell of scalars

true
false

mo_pB/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

fluidPortA

implicit

Hydraulic port A

input

1

fluidPortB

implicit

Hydraulic port B

input

2