Throttle
Throttle
Library
HydraulicsByFluidon/Components/Resistors
Description
The component Throttle is a model of a fluid resistance with to a large extent linear shaped dependence of the VolumeFlow on the pressure difference pA-pB connected to the component.
![](../../../../_mo/_mla/HydraulicsByFluidon3.2.3/HTML/Components/Resistors/../../../Resources/Images/Components/Resistors/LaminarFlow.png)
It is parameterized by the geometric parameters Diameter and Length. The kinetic viscosity of the fluid and its density are considered in their temperature dependency.
![](../../../../_mo/_mla/HydraulicsByFluidon3.2.3/HTML/Components/Resistors/../../../Resources/Images/Components/Resistors/Throttle.png)
The Throttle is suitable for modeling a bore, if the ratio of its length l to its diameter d is comparatively large (approx. l/d > 10). It does not take any inductance into consideration. If desired, a PipeWithoutCapacity or a Pipe is the correct component instead.
Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_diameter | diameter | Diameter | Scalar | |
mo_length | length | Length | Scalar |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_forwardFluidProperties | forwardFluidProperties | Forward fluid properties between ports | Scalar | true |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_volumeFlowA | volumeFlowA | volumeFlowA | Structure | |
mo_volumeFlowA/fixed | fixed | Cell of scalars | true | |
mo_volumeFlowA/start | start | Cell of scalars | ||
mo_volumeFlowB | volumeFlowB | volumeFlowB | Structure | |
mo_volumeFlowB/fixed | fixed | Cell of scalars | true | |
mo_volumeFlowB/start | start | Cell of scalars |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
fluidPortA | implicit | Hydraulic port A | input | 1 |
fluidPortB | implicit | Hydraulic port B | input | 2 |