model StrayLoad "Model of stray load losses dependent on current and speed"
import Modelica.Electrical.QuasiStationary.MultiPhase.Functions.quasiRMS;
extends Modelica.Electrical.QuasiStationary.MultiPhase.Interfaces.OnePort;
extends Modelica.Electrical.Machines.Interfaces.FlangeSupport;
parameter Modelica.Electrical.Machines.Losses.StrayLoadParameters strayLoadParameters "Stray load loss parameters";
extends Modelica.Thermal.HeatTransfer.Interfaces.PartialElementaryConditionalHeatPortWithoutT(useHeatPort = false);
Modelica.SIunits.Current iRMS = quasiRMS(i);
equation
if strayLoadParameters.PRef <= 0 then
tau = 0;
else
tau = -strayLoadParameters.tauRef * (iRMS / strayLoadParameters.IRef) ^ 2 * sign(w) * (abs(w) / strayLoadParameters.wRef) ^ strayLoadParameters.power_w;
end if;
v = {Complex(0, 0) for k in 1:m};
lossPower = -tau * w;
annotation (
defaultComponentName = "strayLoss",
Icon(
coordinateSystem(
preserveAspectRatio = false,
extent = {
{-100, -100},
{100, 100}}),
graphics = {
Rectangle(
extent = {
{-70, 30},
{70, -30}},
lineColor = {85, 170, 255},
pattern = LinePattern.Dot),
Line(
points = {
{-102, 0},
{100, 0}},
color = {85, 170, 255}),
Text(
extent = {
{-150, 90},
{150, 50}},
lineColor = {0, 0, 255},
textString = "%name")}),
Documentation(info = "<html>\n<p>\nStray load losses are modeled similar to standards EN 60034-2 and IEEE 512, i.e., they are dependent on square of current,\nbut without scaling them to zero at no-load current.\n</p>\n<p>\nFor an estimation of dependency on varying angular velocity see:\n<a href=\"modelica://Modelica.Magnetic.QuasiStatic.FundamentalWave.UsersGuide.References\">[Lang1984]</a>\n</p>\n<p>\nThe stray load losses are modeled such way that they do not cause a voltage drop in the electric circuit.\nInstead, the dissipated losses are considered through an equivalent braking torque at the shaft.\n</p>\n<p>\nThe stray load loss torque is\n</p>\n<pre>\n tau = PRef/wRef * (i/IRef)^2 * (w/wRef)^power_w\n</pre>\n<p>\nwhere <code>i</code> is the current of the machine and <code>w</code> is the actual angular velocity.\nThe dependency of the stray load torque on the angular velocity is modeled by the exponent <code>power_w</code>.\n</p>\n<h4>See also</h4>\n<p>\n<a href=\"modelica://Modelica.Electrical.Machines.Losses.StrayLoadParameters\">StrayLoad parameters</a>\n</p>\n<p>\nIf it is desired to neglect stray load losses, set <code>strayLoadParameters.PRef = 0</code> (this is the default).\n</p>\n</html>"));
end StrayLoad;