record TransformerData "Common parameters for transformers"
extends Modelica.Icons.Record;
parameter Real n_phase = 1 "Ratio primary voltage per phase / secondary voltage per phase";
parameter String C1 = "Y" "Choose primary connection"
annotation (choices(
choice = "Y" "Star connection",
choice = "D" "Delta connection"));
parameter String C2 = "y" "Choose secondary connection"
annotation (choices(
choice = "y" "Star connection",
choice = "d" "Delta connection",
choice = "z" "Zig-zag connection"));
parameter Real n = n_phase * (if C1 == "D" and (C2 == "y" or C2 == "z") then sqrt(3) ^ (-1) else if C1 == "Y" and C2 == "d" then sqrt(3) else 1) "Ratio primary voltage (line-to-line) / secondary voltage (line-to-line)"
annotation (Dialog(enable = false));
parameter Modelica.SIunits.Resistance R1 = 0.001666666666667 "Primary resistance per phase at TRef"
annotation (Dialog(tab = "Nominal resistances and inductances"));
parameter Modelica.SIunits.Temperature T1Ref = 293.15 "Reference temperature of primary resistance"
annotation (Dialog(tab = "Nominal resistances and inductances"));
parameter Machines.Thermal.LinearTemperatureCoefficient20 alpha20_1 = 0 "Temperature coefficient of primary resistance at 20 degC"
annotation (Dialog(tab = "Nominal resistances and inductances"));
parameter Modelica.SIunits.Inductance L1sigma = 2.6e-5 "Primary stray inductance per phase"
annotation (Dialog(tab = "Nominal resistances and inductances"));
parameter Modelica.SIunits.Resistance R2 = 0.001666666666667 "Secondary resistance per phase at TRef"
annotation (Dialog(tab = "Nominal resistances and inductances"));
parameter Modelica.SIunits.Temperature T2Ref = 293.15 "Reference temperature of secondary resistance"
annotation (Dialog(tab = "Nominal resistances and inductances"));
parameter Machines.Thermal.LinearTemperatureCoefficient20 alpha20_2 = 0 "Temperature coefficient of secondary resistance at 20 degC"
annotation (Dialog(tab = "Nominal resistances and inductances"));
parameter Modelica.SIunits.Inductance L2sigma = 2.6e-5 "Secondary stray inductance per phase"
annotation (Dialog(tab = "Nominal resistances and inductances"));
annotation (
defaultComponentName = "transformerData",
defaultComponentPrefixes = "parameter",
Documentation(info = "<html>\n<p>Basic parameters of transformers are predefined with default values.</p>\n<p>Note: ratio n is defined between primary / secondary line-to-line voltage;\n therefore the user has to take into account primary and secondary connection!</p>\n</html>"));