record SM_ReluctanceRotorData "Common parameters for synchronous induction machines with reluctance rotor"
import Modelica.Constants.pi;
extends InductionMachineData(Lssigma = 0.1 / (2 * pi * fsNominal));
parameter Modelica.SIunits.Inductance Lmd = 2.9 / (2 * pi * fsNominal) "Stator main field inductance per phase in d-axis"
annotation (Dialog(tab = "Nominal resistances and inductances"));
parameter Modelica.SIunits.Inductance Lmq = 0.9 / (2 * pi * fsNominal) "Stator main field inductance per phase in q-axis"
annotation (Dialog(tab = "Nominal resistances and inductances"));
parameter Boolean useDamperCage = true "Enable / disable damper cage"
annotation (
Evaluate = true,
Dialog(
tab = "Nominal resistances and inductances",
group = "DamperCage"));
parameter Modelica.SIunits.Inductance Lrsigmad = 0.05 / (2 * pi * fsNominal) "Damper stray inductance in d-axis"
annotation (Dialog(
tab = "Nominal resistances and inductances",
group = "DamperCage",
enable = useDamperCage));
parameter Modelica.SIunits.Inductance Lrsigmaq = Lrsigmad "Damper stray inductance in q-axis"
annotation (Dialog(
tab = "Nominal resistances and inductances",
group = "DamperCage",
enable = useDamperCage));
parameter Modelica.SIunits.Resistance Rrd = 0.04 "Damper resistance in d-axis at TRef"
annotation (Dialog(
tab = "Nominal resistances and inductances",
group = "DamperCage",
enable = useDamperCage));
parameter Modelica.SIunits.Resistance Rrq = Rrd "Damper resistance in q-axis at TRef"
annotation (Dialog(
tab = "Nominal resistances and inductances",
group = "DamperCage",
enable = useDamperCage));
parameter Modelica.SIunits.Temperature TrRef = 293.15 "Reference temperature of damper resistances in d- and q-axis"
annotation (Dialog(
tab = "Nominal resistances and inductances",
group = "DamperCage",
enable = useDamperCage));
parameter Machines.Thermal.LinearTemperatureCoefficient20 alpha20r = 0 "Temperature coefficient of damper resistances in d- and q-axis"
annotation (Dialog(
tab = "Nominal resistances and inductances",
group = "DamperCage",
enable = useDamperCage));
annotation (
defaultComponentName = "smrData",
defaultComponentPrefixes = "parameter",
Documentation(info = "<html>\n<p>Basic parameters of synchronous induction machines with reluctance rotor are predefined with default values.</p>\n</html>"));